国产成人精品午夜福利2021-GOGO人体无码一区二区-亚洲制服丝袜中文字幕在线-奇米777四色影视在线看
產(chǎn)品詳情
  • 產(chǎn)品名稱:975A連續(xù) 氧氣,一氧化碳,二氧化碳,甲烷和氫氣分析儀

  • 產(chǎn)品型號(hào):975A連續(xù) 氧氣,一氧化碳,二氧化碳,甲烷和氫氣分析儀
  • 產(chǎn)品廠商:其它品牌
  • 產(chǎn)品文檔:
你添加了1件商品 查看購(gòu)物車
簡(jiǎn)單介紹:
975A連續(xù) 氧氣,一氧化碳,二氧化碳,甲烷和氫氣分析儀 970系列采用高穩(wěn)定性的紅外一氧化碳,二氧化碳,甲烷和同時(shí)測(cè)量探測(cè)器。此外,該分析儀還可以提供與非消耗品,長(zhǎng)壽命電池,氫氣的導(dǎo)熱系數(shù)為一氧化碳,二氧化碳,甲烷和干擾的影響進(jìn)行補(bǔ)償。這可確保始終正確讀出氫氣,不論背景氣體成分。非消耗順磁氧傳感器用于分析。所有傳感器/探測(cè)器的溫度控制或溫度穩(wěn)定性分析的*大補(bǔ)償。
詳情介紹:
975A連續(xù) 氧氣,一氧化碳,二氧化碳,甲烷和氫氣分析儀
970系列采用高穩(wěn)定性的紅外一氧化碳,二氧化碳,甲烷和同時(shí)測(cè)量探測(cè)器。此外,該分析儀還可以提供與非消耗品,長(zhǎng)壽命電池,氫氣的導(dǎo)熱系數(shù)為一氧化碳,二氧化碳,甲烷和干擾的影響進(jìn)行補(bǔ)償。這可確保始終正確讀出氫氣,不論背景氣體成分。非消耗順磁氧傳感器用于分析。所有傳感器/探測(cè)器的溫度控制或溫度穩(wěn)定性分析的*大補(bǔ)償。

970 Series

larger image
 

The Nova 970 Series Syn-Gas Analyzer System has been designed with the flexibility and robustness required in the experimental and developmental environments that characterize syn-gas applications.

The Nova 970 Series utilizes high-stability infrared detectors for the simultaneous measurement of CO, CO2, and CH4. In addition, the analyzer can also be supplied with a non-consumable, long-life thermal conductivity cell for H2 that compensates for the interference effects of CO, CO2, and CH4. This ensures that H2 will always read correctly regardless of the background gas composition.  A non-depleting paramagnetic sensor is used for O2 analysis.  All sensors/detectors are temperature-controlled or temperature-compensated for maximum analytical stability.  Auto calibration functionality allows easy calibration without user intervention.  The included Serial Output Package allows connection of analyzer to personal computers via a choice of USB/RS-232/RS-485. Data recording software is also included.


 




















Specifications · Applications · Features · Options · Calibration

Specifications  

Method of Detection

NDIR infrared detector for CO, CO2 and CH4
Paramagnetic sensor for O2
Thermal Conductivity Cell for H2

Ranges Available

0-2.0%, 0-25.0%, 0-50.0%, 0-100.0% O2
0-2.0%, 0-50.0%, 0-100.0% CH4
0-2.0%, 0-50.0%, 0-100.0% CO
0-2.0%, 0-50.0%, 0-100.0% CO2
0-2.0%, 0-50.0%, 0-100.0% H2

Resolution

 

0.1% for all gases

Accuracy & Repeatability

± 1.5% of full scale on all gases

Drift

Less than 2% of full scale per month

Response Time (T-90)

20-30 seconds to 90% step change

Ambient Temperature Range

40-104 °F (4-40°C). Optional -22-158 °F (-30-70 °C) with Outdoor Packages

Linearity

± 1.5% of full scale

Size & Weight

 

24" H x 24" W x 10" D @ 90 lbs (61 x 61 x 25 cm @ 20 kg)

Power

115 VAC 60 Hz (220 VAC 50 Hz available)

Output Options

Isolated 4-20 mA standard
RS232, RS485, MODBUS®, Ethernet outputs optional

Alarms

High and/or low alarm contacts available, relay contacts SPDT 5A @ 220 VAC rating.

 

Applications  

For continuous monitoring of any combination of gases such as oxygen (O2), methane (CH4), carbon dioxide (CO2), carbon monoxide (CO) and hydrogen (H2) for experimental, developmental and industrial processes including syn-gas atmospheres.


 

Features  

  • Sensitive infrared detectors for CO, CO2 and CH4
  • Thermal conductivity cell for H2
  • Non-depleting paramagnetic oxygen sensor
  • Sensors/detectors temperature controlled or compensated for maximum analytical stability
  • H2 reading is compensated for the interference effects of the other gases measured
  • High ranges on each channel available
  • Touch-screen display for gas readings
  • Built-in sample pump or pressure regulator
  • Automatic calibration & serial output package
  • Isolated 4-20 mA analog recorder outputs
  • Durable internal lines & sample components
  • Automatic moisture removal system included


     

Options  

  • Calculations performed on gas readings such as gas ratios and heating value of flammable gases
  • Hi/Low gas, low flow and other alarms available
  • Sample conditioning systems available for acidic gas and dust
  • Cabinet purge system available for use in hazardous areas
  • Outdoor packages available for operation from -22 to 158 °F (-30 to 70 °C)
  • Cabinet coolers can be fitted to most models
  • Heated filters and high temperature probes


     

Calibration  

  • Ambient air for O2 and to zero all other gases
  • Analyzed calibration gas with representative concentrations for span of all other gases

     














* 請(qǐng)輸入您的名字,方便我們和您聯(lián)系
* 請(qǐng)輸入您的電話,方便客服及時(shí)解答您的問(wèn)題
* 請(qǐng)輸入您詳情地址,方便詳細(xì)提供當(dāng)?shù)氐氖袌?chǎng)訊息