国产成人精品午夜福利2021-GOGO人体无码一区二区-亚洲制服丝袜中文字幕在线-奇米777四色影视在线看
產(chǎn)品詳情
  • 產(chǎn)品名稱:GMA 100 系列氣體控制卡

  • 產(chǎn)品型號:GMA 100 系列氣體控制卡
  • 產(chǎn)品廠商:其它品牌
  • 產(chǎn)品文檔:
你添加了1件商品 查看購物車
簡單介紹:
GMA 100 系列氣體控制卡 GMA 101系列氣體控制卡可以帶1個探測器; GMA 103系列氣體控制卡可以帶3個探測器; GMA 104系列氣體控制卡可以帶4個探測器;
詳情介紹:
GMA 100 系列氣體控制卡
GMA 101系列氣體控制卡可以帶1個探測器;
GMA 103系列氣體控制卡可以帶3個探測器;
GMA 104系列氣體控制卡可以帶4個探測器;

 

19" Rack-mounting

Microprocessor-based gas control system

The GMA101 system is a microprocessor-based, 19” rack mounted gas control system for all measuring functions. Depending on the transmitter type connected, the GMA100 is a complete gas detection system for detection of flammable and toxic hazards, and oxygen.

The GMA100’s highly flexible construction and variety of functions make the system suitable for all gas detection tasks. 3 alarm levels can be set. Additional relay and alarm functions can be configured.All transmitter types can be connected. GMA100 controllers support both 2- and 3-wire devices. The controller supplies power to the attached transmitters, depending on system configuration a large number of measuring points can be monitored at the same time.

GMA101 system versions

GMA101 for 1 transmitter for control of 1 measuring point. 3 alarm thresholds can be set.

GMA103 for 3 transmitters for control of up to 3 measuring points. 1 alarm threshold for each transmitter.

GMA104 for 4 transmitters for the control of to to 4 measuring points. 3 alarm thresholds as common alarms can be set.

Safe monitoring
Three alarm thresholds can be individually adjusted in the GMA100 series controllers. In addition, each controller has four floating relays which can be switched normally open or closed. These relays can activate external alarm devices, or switch on ventilation, for example. Gas leaks are rapidly detected.

Simple operation
Gas concentration is continuously shown on a 3-digit LED display. Gas concentration, gas type and detection range can all be displayed via a simple button push. Zero and span adjustment can also be performed simply via the simple operation from push buttons. The controller has a min/max memory that enables the user to check the exact concentrations encountered after a gas alarm has occurred. In addition, the highest or lowest measured value is stored and displayed in the LED display. A 4-20mA output (GMA 101) is available to transmit gas measurement readings to external devices.

The advantages at a glance

  • Simple operation
  • Menu-led service operation
  • Configurable relay switching functions
  • 4 relays for 3 alarms and 1 fault signal
  • Linear output signal of 4-20 mA
  • Numerous auxiliary functions for measured value memory, delta alarm or alarm delay
  • Transmitter calibration via simple button push

ATEX-Certification: II (2)G  C 0158 BVS 03 ATEX G006 X   0158

* 請輸入您的名字,方便我們和您聯(lián)系
* 請輸入您的電話,方便客服及時解答您的問題
* 請輸入您詳情地址,方便詳細(xì)提供當(dāng)?shù)氐氖袌鲇嵪?