国产成人精品午夜福利2021-GOGO人体无码一区二区-亚洲制服丝袜中文字幕在线-奇米777四色影视在线看
產品詳情
  • 產品名稱:8000系列高爐爐頂煤氣連續(xù)分析儀

  • 產品型號:8000系列高爐爐頂煤氣連續(xù)分析儀
  • 產品廠商:其它品牌
  • 產品文檔:
你添加了1件商品 查看購物車
簡單介紹:
8000系列高爐爐頂煤氣連續(xù)分析儀 設計用于連續(xù)監(jiān)測氧氣,一氧化碳,二氧化碳,和/或從鼓風爐或其他連續(xù)工業(yè)過程氣體在氫氣的氣體濃度數據,源源不斷地是至關重要的.
詳情介紹:
8000系列高爐爐頂煤氣連續(xù)分析儀
設計用于連續(xù)監(jiān)測氧氣,一氧化碳,二氧化碳,和/或從鼓風爐或其他連續(xù)工業(yè)過程氣體在氫氣的氣體濃度數據,源源不斷地是至關重要的.

8000-Series-large-pic

larger image
Designed for the continuous monitoring of O2, CO, CO2, and/or H2 gases from blast furnaces or other continuous industrial processes where an uninterrupted stream of gas concentration data is critical. Calculated values of BTU, N2 and efficiency are also available.

Search Items


Request QuoteCompare Items   Results per Page : 
  Results 1 - 9 of 9   1 
 
 

Item #

Enclosure and Mounting Details

Resolution

Response Time (T-90)

Power

Analyzer Type

Hazardous Area Rating Options

Model 8002 Blast Furnace Top Gas Analyzer, CO and CO2 0.1% for all gases measured T90 < 30 seconds not including transmission time to process 115 VAC, 60 Hz
220 VAC, 60 Hz
Blast Furnace Top Gas Analyzer General Purpose, Non-Hazardous
Model 8003 Blast Furnace Top Gas Analyzer, H2, CO, and CO2 with H2 compensation 0.1% for all gases measured T90 < 30 seconds not including transmission time to process 115 VAC, 60 Hz
220 VAC, 60 Hz
Blast Furnace Top Gas Analyzer General Purpose, Non-Hazardous
Model 8004 Blast Furnace Top Gas Analyzer, H2, O2, CO, and CO2 with H2 compensation 0.1% for all gases measured T90 < 30 seconds not including transmission time to process 115 VAC, 60 Hz
220 VAC, 60 Hz
Blast Furnace Top Gas Analyzer General Purpose, Non-Hazardous
Model 8006 Blast Furnace Top Gas Analyzer, H2, O2, CO, and CO2 with H2 compensation, N2, BTU and efficiency calculation 0.1% for all gases measured T90 < 30 seconds not including transmission time to process 115 VAC, 60 Hz
220 VAC, 60 Hz
Blast Furnace Top Gas Analyzer General Purpose, Non-Hazardous
Model 8000D2 Blast Furnace Top Gas Analyzer - 8000 Series 0.1% for all gases measured T90 < 30 seconds not including transmission time to process 115 VAC, 60 Hz
220 VAC, 60 Hz
Blast Furnace Top Gas Analyzer Class 1, Div 2 Hazardous Area Rating
Model 8002-D2 Blast Furnace Top Gas Analyzer, CO and CO2 0.1% for all gases measured T90 < 30 seconds not including transmission time to process 115 VAC, 60 Hz
220 VAC, 60 Hz
Blast Furnace Top Gas Analyzer Class 1, Div 2 Hazardous Area Rating
Model 8003-D2 Blast Furnace Top Gas Analyzer, H2, CO, and CO2 with H2 compensation 0.1% for all gases measured T90 < 30 seconds not including transmission time to process 115 VAC, 60 Hz
220 VAC, 60 Hz
Blast Furnace Top Gas Analyzer Class 1, Div 2 Hazardous Area Rating
Model 8004-D2 Blast Furnace Top Gas Analyzer, H2, O2, CO, and CO2 with H2 compensation 0.1% for all gases measured T90 < 30 seconds not including transmission time to process 115 VAC, 60 Hz
220 VAC, 60 Hz
Blast Furnace Top Gas Analyzer Class 1, Div 2 Hazardous Area Rating
Model 8006-D2 Blast Furnace Top Gas Analyzer, H2, O2, CO, and CO2 with H2 compensation, N2, BTU and efficiency calculation 0.1% for all gases measured T90 < 30 seconds not including transmission time to process 115 VAC, 60 Hz
220 VAC, 60 Hz
Blast Furnace Top Gas Analyzer Class 1, Div 2 Hazardous Area Rating

* 請輸入您的名字,方便我們和您聯(lián)系
* 請輸入您的電話,方便客服及時解答您的問題
* 請輸入您詳情地址,方便詳細提供當地的市場訊息