- 比利時(shí)StuvEX防爆與防火設(shè)備
- 美國(guó)RCS腐蝕產(chǎn)品監(jiān)測(cè)設(shè)備
- 盧森堡ROTAREX羅達(dá)萊克斯滅火系...
- 意大利GM SISTEMI火花探測(cè)及...
- 西班牙ADIX安迪克斯抑制爆炸系統(tǒng)
- 備盈倍BS&B防爆**系統(tǒng)
- 賀爾碧格Newson Gale防爆靜...
- 賀爾碧格hoerbiger防爆**系...
- 意大利Aircom愛(ài)科粉塵防爆設(shè)備
- 法國(guó)Stif斯緹福粉塵防爆設(shè)備
- 西班牙Adix安迪克斯隔爆閥抑制系統(tǒng)...
- 瑞士Rico瑞科爆炸隔離閥
- 意大利Control logic康洛...
- 意大利Control logic康洛...
- 意大利科恩除塵和防爆產(chǎn)品
- 美國(guó)Argus火花和金屬探測(cè)以及回收...
- 美國(guó)Edwards愛(ài)德華消防報(bào)警系統(tǒng)
- 美國(guó)Kidde凱德廚房滅火和空氣采樣...
- 美國(guó)Marioff HI-FOG高壓...
- 挪威納斯克激光氣體分析儀
- 德國(guó)Rembe認(rèn)必泄壓爆破片及隔離塵...
- 英國(guó)Amal阻火器
- 英國(guó)Marvac呼吸閥和緊急泄放閥以...
- 英國(guó)Marston防爆板和爆破片
- 美國(guó)ZOOK防爆板
- 瑞士Rico-Ventex隔爆閥
- 德國(guó)GreCon格雷康火花探測(cè)器以及...
- 德國(guó)Eltex埃爾特克斯防爆靜電接地...
- 美國(guó)迪康氣體檢測(cè)設(shè)備
- 美國(guó)PAC實(shí)驗(yàn)室和在線分析儀器
- 奧德姆/安姆特儀器產(chǎn)品
- 美盛環(huán)境監(jiān)測(cè)行業(yè)成套系統(tǒng)工程
- 美盛流體污染控制,過(guò)濾,分離凈化產(chǎn)品
- 美國(guó)Norman不銹鋼高壓過(guò)濾器
- 美國(guó)施羅德過(guò)濾器以及過(guò)濾系統(tǒng)
- 韓國(guó)杜科給水設(shè)備以及泵系統(tǒng)
- 美國(guó)Cameron卡麥龍過(guò)程控制和閥...
- 美國(guó)BARTON測(cè)量?jī)x器儀表
- 美國(guó)NUFLO儀表產(chǎn)品
- 美國(guó)clif mock采樣設(shè)備和系統(tǒng)
- Caldon超聲波技術(shù)產(chǎn)品
- 美國(guó)Cameron/Barton卡麥...
- 美國(guó)Pentail濱特爾油液凈化設(shè)備...
- 韓國(guó)雷尊泰克REZONTECH火焰探...
- 韓國(guó)CSA Bestouch火焰探測(cè)...
- 科馬特泰克色譜技術(shù)產(chǎn)品
- 英國(guó)愛(ài)丁堡Edinburgh ins...
- 歐美Cerex/AquaRead等進(jìn)...
- 歐文凱利自控閥設(shè)備
- 德?tīng)柛馜raeger**檢測(cè)設(shè)備
- 美國(guó)Det-tronics火焰探測(cè)器...
- 泵閥控制
- 美國(guó)Honeywell生命**產(chǎn)品
- 密析爾濕度和露點(diǎn)儀表
- 美國(guó)TIF公司鹵素檢漏儀
- 美國(guó)Teledyne Analyti...
- 美國(guó)泰科SCOTT健康和**
- 日本日置HIOKI電測(cè)產(chǎn)品
- 英國(guó)梅克羅尼(MICRONICS)超...
- 美國(guó)AII氧分析儀
3520系列微量氧分析儀是一種重量輕,緊湊的便攜式氧氣分析儀,設(shè)計(jì)用于工業(yè)和商業(yè)應(yīng)用,需要**,現(xiàn)場(chǎng)測(cè)量氧氣的場(chǎng)合
.jpg)
The Series 3520 Trace Oxygen Analyzer is a light-weight, compact portable oxygen analyzer designed for industrial and commercial applications where accurate, spot oxygen measurements need to be made.
- Features and Benefits
- System Description
- Specifications
- Rear View Photo
- Download PDF Data Sheet
(Requires Adobe Acrobat Reader) - Contact Us
Features | Benefits |
State-of-the-Art Sensor Technology |
High Precision Measurements |
Light Weight/Compact Design | Easy to Carry and Transport |
Rapid Speed of Respons | Senses Oxygen Changes in Seconds |
Built-in NICAD Batteries | Provides Hours of Continuous Operation |
Uses Standard NICAD’s | Replacement Batteries Found World-Wide |
Minimum Maintenance | Low Cost of Ownership |
System Description
The analyzer is powered from standard NICAD batteries that are mounted internally within the enclosure. Also included is an AC/DC adapter that when in use, allows the analyzer to be operated while the NICAD batteries are being recharged. Optional equipment includes a sample pump, pressure regulators, and sample filters. The Series 3520 is the product of choice with single measuring ranges from 0-50 parts per million to 0-10,000 parts per million.
The Series 3520 Portable Trace Oxygen Analyzer is a high precision instrument designed to provide accurate trace oxygen measurements in a variety of laboratory and process gases. The Series 3520 can be configured with one of several measuring ranges from 0-50 parts per million (ppm) to 0-10,000 ppm.
The Series 3520 is equipped with either a 3-1/2 or 4-1/2 digit liquid crystal display (depending on the range selected), built-in NICAD batteries, and an AC adapter that provides the ability to recharge the NICAD batteries even while powering the analyzer from the adapter. The 3520 features an advanced electrochemical oxygen sensor. The improved mechanical design of the sensor ensures longer life and virtually eliminates leakage of caustic electrolyte, a nagging problem associated with sensors that require periodic electrolyte maintenance. The output from the sensor is temperature compensated. In addition, the sensor is equipped with manual isolation valves so that during times of inactivity, the sensor can be kept inerted and ready for use.
Learn about about sample system handling for oxygen and carbon dioxide analyzers
A major advantage of the Series 3520 is that it does not require users to apply a correction factor to the readings when exposed to different gas compositions. With other analyzer types, if correction factors are not applied, readings can be off by a factor of three!
Back To Top
Specifications
Measurement Ranges: 0-50, 0-100, 0-500, 0-1,000, 0-5,000, and 0-10,000 PPM
Accuracy: ±1% of full scale
Linearity: ±1% of full scale.
Response Time: 90% of full scale in <20 seconds typical
Sensor Type: Electrochemical
Temperature Compensation: Standard
Operation Temperature Range: 40º to 100ºF (5º to 38º C)
Sample Gas Pressure Limits: 0.1 to 1.0 psig (1.04 kg/cm² to 1.10 kg/cm²)
Sample Flow Rate: 1.0 to 2.0 SCFH (0.5 to 1.0 liters/minute)
Power Source: Rechargeable NICAD batteries or 115 VAC/60 Hz using the AC adapter
Analog Output: Not available
Warranty: Two years electronics/1 year sensor
Enclosure: Polycarbonate-rated NEMA 1
Display: 3-1/2 or 4-1/2 digit liquid crystal display
Gas Connections: 1/4”compression fittings
Dimensions: D. 5.8” H x 8.8” W x 3.4” D
Weight: <4 pounds
Back To Top
Learn more about oxygen sensor types
Rear View Photo
.jpg)